This course teaches how to create a safer M12 CNC controller breakout board for an Avid CNC router with specific components. The learning outcomes include understanding the difference between normally-open and normally-closed sensors, designing circuits, assembling PCBs, testing, and troubleshooting. The course utilizes tools such as a multimeter, soldering station, screwdriver set, and power supply. The teaching method involves a practical demonstration of creating and testing the breakout board. This course is intended for individuals interested in CNC projects, specifically those using inductive proximity sensors with Avid CNC setups.
Overview
Syllabus
Normally-Open vs Normally-Closed
The Circuit Design
PCB Assembly
Testing
Fixing the Glitch
SMT Sample Books
The Modified Board
Re-Testing
A Better Solution
More Board Surgery
Re-Re-Testing
Conclusions
Taught by
Clough42